Maintenance Object Repair Procedures
555-233-123
10-190
Issue 4 May 2002
Receive FIFO Error Counter Test (#625)
This test reads and clears the BRI port’s Receive FIFO error counter maintained
on the TN800 circuit pack. This counter is incremented by the circuit pack when it
detects an overflow of its receive buffers. The test passes if the value of the
counter is 0 (that is, the error is cleared). If the counter is not zero, the test fails,
and the value of the counter is displayed in the Error Code field.
This error can occur if signaling frames are being received from a Packet Bus at a
rate sufficient to overflow the receive buffers on the circuit pack for a port or if
hardware fault is causing the receive buffers not to be emptied properly. This test
is useful for verifying the repair of the problem.
Table 10-62.
TEST #624 Layer 1 Transmission Error Counter Test
Error
Code
Test
Result
Description/Recommendation
2000
ABORT
Response was not received from the circuit pack within the
allowable time period.
1. If the test aborts repeatedly a maximum of 5 times, reset
the circuit pack using the busyout board PCSS and reset
board PCSS commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate necessary system resources to run test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Any
FAIL
The TN800 circuit pack is still detecting errors of this type. The
Error Code field contains the value of this counter.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to fail, review the results of other tests
in the Long Test Sequence. Note the results of the Level 1
Status Inquiry test. Follow the repair procedures for any of
the executed tests if they fail. Otherwise, go to the next
step.
3. Replace the circuit pack.
PASS
The Layer 1 Transmission error counter was read correctly
and has a value of 0.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...