Maintenance Object Repair Procedures
555-233-123
10-794
Issue 4 May 2002
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2060
ABORT
The link on the Packet Bus being used to perform the test has
failed.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, check for problems with the
Packet Control circuit pack (look for PKT-CTL errors).
2500
ABORT
An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1
FAIL
The test did not detect the test tone through the loop around
connection.
NOTE:
If the circuit pack is a TN570, the packet portion of this
test was not run since the circuit portion failed.
1. Test the Active Tone-Clock on the Port Network that
contains the defective Expansion Interface circuit pack to
verify that dial tone is being supplied.
2. If the Tone-Clock is healthy, issue the test board PCSS
long command on the Expansion Interface circuit pack.
3. If this test continues to fail, replace the Expansion
Interface circuit pack or transceiver. Then, reissue the test
board PCSS long command on the new Expansion
Interface circuit pack.
Table 10-293.
TEST #242 Expansion Interface Lightwave
Transceiver Loop Around Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...