
CARR-POW (Carrier Port Power Unit) for DC-Powered
Systems
Issue 4 May 2002
10-389
555-233-123
Power Unit Query Test (#127)
This test queries the Maintenance/Tape Processor in a Standard system PPN, the
Duplication Interface circuit pack in a PPN for a High or Critical Reliability system,
or the EPN Maintenance circuit pack in an EPN multicarrier cabinet system for the
status of the pair of port carrier power units in the specified carrier. If both port
carrier units are on and functioning, the test passes. If both are not on and
functioning, the test fails.
Table 10-144.
TEST #127 Power Unit Query Test
Error
Code
Test
Result
Description/Recommendation
1000
ABORT
System resources required to run this test are not available.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2029
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...