Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-484
Issue 4 May 2002
Output
The following output example for the test spe-standby command assumes that
the standby SPE is located in carrier B. The responses display on a test-by-test
basis with one line of data for each test result.
Field descriptions
Port
The port address: cabinet-carrier-slot-circuit
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name
Alternate means of identifying the maintenance object. This
field contains the extension when the object is a data
module.
Test No
Test being executed
Result
Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of the codes by test number for
each MO.
test spe-standby SPE A
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01B SHDW-CIR 285 PASS
01B SHDW-CIR 284 PASS
01B SPE-SELECT 278 PASS
01B DUPINT 315 PASS
. . . .
. . . .
. . . .
Command Successfully Completed