ANNOUNCE (Announce)
Issue 4 May 2002
10-167
555-233-123
Hardware Error Log Entries
Notes:
a. Error occurred while saving announcements. (See Table 10-42 in the next
section for an explanation of Aux Data and for recommended repair
actions.)
b. Error occurred while saving announcements to the standby SPE. (See
Table 10-42 in the next section for an explanation of Aux Data and for
recommended repair actions.)
c. User pressed cancel while announcements were being saved by the active
PE.
d. User pressed cancel while announcements were being saved by the
standby PE.
e. Error occurred while restoring announcements. (See Table 10-42 in the
next section for an explanation of Aux Data and for recommended repair
actions.)
f. The port field for this error contained the active PE complex when the error
occurred.
ANNOUNCE Error Log Entries
Error Type
Aux
Data
Associated
Test
Alarm
Level
On/Off
Board
Test to Clear Value
1(a)(f)
any
None
257(b)(f)
any
None
513(c)(f)
0
None
769(d)(f)
0
None
1025(e)(f)
any
None