TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Issue 4 May 2002
10-1695
555-233-123
2036
2037
ABORT
Internal system error
1. Follow the recommendation for ABORT code 2012.
2038
2039
ABORT
A problem occurred while trying to read the test data.
1. Wait one minute and then try again.
2. If the test aborts again in the same manner, there is a
serious internal problem. If so, escalate the problem.
2040
ABORT
Internal system error
1. Follow the recommendations for ABORT code 2012.
2041
ABORT
The call has timed out, perhaps because of a lack of system
resources.
1. Follow the recommendations for ABORT code 2035.
2066
ABORT
Could not establish test call.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2067
ABORT
The call has timed out, perhaps because of a lack of system
resources.
1. Follow the recommendations for ABORT code 2035.
2074
ABORT
Bit and Block Error query failed.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, there may be a serious
internal problem with M/T-DIG (Maintenance/Test Digital
Port). If this is the case, refer to the M/T-DIG
(Maintenance/Test Digital Port) Maintenance
documentation.
2075
ABORT
Internal system error
1. Follow the recommendations for ABORT code 2012.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-624.
TEST #258 ISDN TEST Call — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...