Maintenance Object Repair Procedures
555-233-123
10-1378
Issue 4 May 2002
MTP Sanity Handshake Test (#106)
This test is a nondestructive test. The MTP Sanity Handshake Test is simply a
query from a maintenance process to the MTP. The MTP must reply for the test to
pass.
Table 10-510.
TEST #106 MTP Sanity Handshake Test
Error Code
Test
Result
Description/Recommendation
100
ABORT
The test did not complete within the allowable time period.
1. Retry the command.
1000
ABORT
System software resources required for this test are not
available.
1. Retry at 1-minute intervals a maximum of 5 times.
1029 2014
2015 2016
2017 2018
2020 2022
2024 2025
2051
ABORT
Refer to “STBY-SPE” for a description of these error
codes.
2000
ABORT
The response to the test request was not received within
the allowable time period.
2033
ABORT
Internal system error.
1. Repeat the command at 1-minute intervals a
maximum of 5 times.
FAIL
The MTP did not respond to the Sanity Handshake Query.
1. Re-enter command with the “long” option.
2. If the test continues to fail, replace the Processor
circuit pack.
NOTE:
If you replace the Processor circuit pack, you
need to obtain a new license file.
PASS
The MTP responded to the Sanity Handshake Query.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...