The output of the CI and PAI cards go directly to the TN780 Tone-Clock circuit
pack via two 25-pair amp-terminated cables. All of the cards have red and/or
green LEDs for providing status or alarm indications. The following table shows
the Stratum 3 Clock LED indications.
NOTE:
The abbreviations used in the table were defined previously with the
exception of SRC (source) and PLL (Phase Locked Loop).
NOTE:
When looking in the Stratum 3 cabinet, “A” card is on the left and “B” card is
on the right.
Table 10-579.
Stratum 3 Clock LED Indications
Card
Name
Color
Indication
PAI
REF A
Red
Loss of input reference A or CI A failed
REF B
Red
Loss of input reference B or CI A failed
ST A
Red
Failed Stratum 3 clock A
ST B
Red
Failed Stratum 3 clock B
PWR A
Green
-48VDC A present
PWR B
Green
-48VDC B present
CI
FAIL
Red
Card failure
DS1
Green
DS1 source present
CC
Green
Composite clock source
1
present
1
Composite Clock source refers to the protocol used to electrically transfer timing from
the Stratum 3 clock to the PBX switch.
SRC ACTIVE
Green
Card is currently on-line
ST3
FAIL
Red
Card failure
LOCK
Red
PLL lost sync with reference or holdover mode
REF A
Red
Timing Reference from CI A
REF B
Red
Timing Reference from CI B
TOC
FAIL
Red
Card failure
PORT ALM
Red
Output port alarm (one or more)
ST
Green
Reference present from ST clock
INPUT
Green
Reference present from CI
500’
Green
500 feet phase advance
1000’
Green
1000 feet phase advance
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...