MEDPROPT (TN802/TN2302 MED PRO DSP PORT)
Issue 4 May 2002
10-1085
555-233-123
Table 10-408.
TDM NIC Looparound Test (#1380)
Error
Code
Test
Result
Description/Recommendation
1002
ABORT
The system could not allocate timeslots for the test. The system
may be under heavy traffic conditions or it may have timeslots out
of service due to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, retry the command at 1-minute intervals
a maximum of 3 times.
2. If system has TDM-BUS errors, clear any errors, and
retry the command at 1-minute intervals a maximum of
3 times.
3. If the command continues to abort, escalate the
problem.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors. Even if there are no
TTR-LEV errors, there may not be a Tone Detector
available on the network that contains the circuit pack
being tested. Verify that there is at least one Tone
Detector on this network. This does not harm the
system.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at
1-minute intervals a maximum of 3 times.
2000
ABORT
Response to the test was not received in the allowable time
period.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
2801
ABORT
The TN802B/TN2302 Media Processor board has not been
administered on the ip-interfaces form.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...