
Maintenance Object Repair Procedures
555-233-123
10-2000
Issue 4 May 2002
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the UDS1
Interface circuit pack to ensure that the wideband access endpoint port’s
translation is correct.
Table 10-719.
TEST #36 Audit and Update Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal System Error.
1. Retry the command at one minute intervals a maximum of
5 times.
1006
ABORT
The port is out-of-service. If the port is busied out:
1. Issue release access-endpoint <extension> command
to put the port back into in-service.
2. Retry the test command.
If the port is not busied out:
1. Check the error and alarm logs for WAE-PORT and
UDS1-BD errors and alarms. Follow the recommended
repair procedures.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at one minute intervals a maximum of
5 times.
FAIL
Internal system error.
1. Retry the command at one minute intervals a maximum of
5 times.
PASS
Port translation has been updated successfully.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...