Maintenance Object Repair Procedures
555-233-123
10-1456
Issue 4 May 2002
6
ABORT
This port may have been busied out by a system technician.
1. Look in the Error Log for Error Type 18 (port busied
out) for this port. If this error is present, release the
port using the release station command.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum
of 5 times.
1000
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum
of 5 times.
1392
ABORT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the
display port command (the display shows that the
port is a TTI port) or the list config command (the
display shows a
t
for the port).
2. If either list config or display port indicate that the
port is not a TTI port, escalate the problem. If both
commands indicate that the port is a TTI port, the
abort is correct, and no action is necessary.
2000
ABORT
Response to the test was not received in the allowable time
period.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
PASS
Station Audits passed. This Digital Port circuit pack is functioning
properly.
1. If complaints persist, investigate by using other port
tests, and by examining the station, wiring, and
connections.
Table 10-552.
TEST #17 Station (Digital) Audits Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...