Maintenance Object Repair Procedures
555-233-123
10-1182
Issue 4 May 2002
PDMODULE, TDMODULE (Data
Module)
As illustrated in
, data modules provide an interface
between the system TN754, TN784, TN413 [G3iV2-386], or TN754 [G3iV2-386]
Digital Line circuit pack and data equipment such as terminals, host computers,
and modems. Data modules are used for both dial-up and permanent
circuit-switched data calls. DA data modules provide this interface when the
system uses a TN2136 [G3iV2-386] Digital Line circuit pack.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier
where the circuit pack is located (for example, 01, 02, ..., etc.); and pp is the 2-digit port
number (for example, 01).
Full Name of MO
PDMODULE
2,3
2
The DTDM is considered to be part of the DIG-LINE MO. Refer to the Digital Line
testing section for DTDM or linked Data Adapter (DA) failures.
3
Some of the alarms that are logged due to PDMODULE and TDMODULE test failures
may be related to circuit pack problems reported during the Common Port Circuit Pack
testing phase. Refer to the XXX-BD (Common Port Circuit Pack) Maintenance
documentation for information about testing the Digital Line circuit packs.
MINOR
test port PCSSpp l
Processor Data
Module
PDMODULE
WARNING
test port PCSSpp sh
Processor Data
Module
TDMODULE
MINOR
test port PCSSpp l
Trunk Data Module
TDMODULE
WARNING
test port PCSSpp sh
Trunk Data Module
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...