5013
FAIL
The Modem Pool Port did not respond with an on-hook
message when the connection to the Data Channel was
broken, indicating a likely problem with the TN758 Pooled
Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
5014
ABORT
The Network Control Channel allocated for this test did not
respond correctly to the setup message sent to it after the
connection was established.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit pack
using the test data-module command (refer to the
DATA-CHL maintenance strategy).
3. If the DATA-CHL circuit pack tests pass, escalate the
problem.
5015
ABORT
Data Channels 1 and/or 3 have not been administered.
1. Administer the Data Channels and retest.
Table 10-417.
TEST #98 Modem Pool Conversion Resource Loop Around Test
— Continued