SPE-SELEC (SPE Select Switch)
Issue 4 May 2002
10-1513
555-233-123
Error Log Entries and Test to Clear Values
Notes:
a. The Warning alarm is upgraded to Major if the error is not resolved in six
hours.
b. Determine the carrier (a or b) by the Port field in the Error or Alarm Log. For
SPE-SELEC, the Port field is 1A (test duplication interface a) or 1B (test
duplication interface b).
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the Duplication Interface Circuit Pack Status Query
Test, for example, you may also clear errors generated from other tests in the
testing sequence.
Table 10-573.
SPE Select Switch Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test duplication-interface 1C sh r 1
1
Any
SPE Select Query
Test (#278)
WARNING
/ MAJOR
2
2
This error type initially raises a Warning alarm. If this error type persists and alarms are not
downgraded on this MO due to the values of set options, then, after a period of time, a Major alarm
is raised.
OFF
test duplication-interface 1C sh r
257
any
SPE Select Query
Test (#278)
WARNING
/ MAJOR
OFF
test duplication-interface 1C sh r 2
Table 10-574.
System Technician-Demanded Tests: DUPINT
Order of Investigation
Short Test Sequence
Long Test Sequence
D/ND
1
Active
Standby
Active
Standby
Duplication Interface Circuit Pack Status
Query Test (#315)
X
X
X
X
ND
Duplication Interface Circuit Pack Sanity
Maze Test (#277)
X
X
X
X
ND
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...