SHDW-LNK (Memory Shadowing Link)
Issue 4 May 2002
10-1501
555-233-123
2047
FAIL
The Standby SPE Maintenance/Tape Processor released the
Standby SPE processor with a request to clear Standby SPE
Memory; Standby SPE Memory was not successfully cleared.
1. Check for Standby SPE Processor errors and alarms. Refer
to PROCR (80286 Processor Circuit Pack) Maintenance
documentation and follow the prescribed procedures.
2. Check for Standby SPE Memory errors and alarms. Refer to
MEM-BD (Memory) Maintenance documentation and follow
the prescribed procedures.
3. If all problems found in Steps 1 and 2 have now been
repaired, proceed with Step 5. If no problems were found in
Steps 1 and 2, proceed with Step 4.
Table 10-572.
TEST #318 Shadow Link Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...