Maintenance Object Repair Procedures
555-233-123
10-1170
Issue 4 May 2002
1004
ABORT
The test was aborted because the port was seized by a user for
a valid call. Use status station command to determine the
service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You
must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, and the port is not in use,
escalate the problem.
1020
ABORT
The test did not run due to an an already existing error on the
specific port or due to a more general error on the circuit pack.
1. Examine the error log for existing errors against this port or
the circuit pack and attempt to diagnose the already existing
error. (Error code 1793 indicates a problem with the DS1
interface board, and any problems on the associated
DS1-BD or UDS1-BD should be resolved first.)
2000
ABORT
Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test aborts with error code 2000 again, run short test
sequence on the associated DS1-BD or UDS1-BD. If tests
138 through 145 on the associated DS1-BD or UDS1-BD
are also aborting with error code 2000, hyperactivity on the
board or facility is indicated. In this case, the hyperactivity
problem should be dealt with first.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at one-minute intervals a maximum of 5
times.
Table 10-441.
TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...