Maintenance Object Repair Procedures
555-233-123
10-90
Issue 4 May 2002
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to “TTR-LEV (TTR Level)” Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to “TONE-PT (Tone Generator)” Maintenance
documentation.
3. If neither condition exists, retry the test at 1-minute
intervals a maximum of 5 times.
1004
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the station extension. Use
the status station command to determine the service state of
the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1005
ABORT
The test was aborted due to a configuration problem. This
code will result under either of the following conditions:
1. This test may not be applicable, or it may be disruptive to
terminal equipment other than a voice terminal (for
example, the modem pool member or music on hold).
2. The circuit pack is one of the following:
— TN742 vintages 13,14 and 15
— TN769 vintages 3,4 and 5
1018
ABORT
Test disabled via administration. The default for the 'Test' field
on the 'Station' form is 'y'; thus, you may want to determine
why this field has been set to 'n' on this station (this may be
due to the ringing application test 48, which can be customer
or terminal disturbing).
1. To enable the test for a particular station, enter change
station extension and set the ‘Test?’ field on the ‘Station
Form’ to ‘y.’
Table 10-32.
TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...