Maintenance Object Repair Procedures
555-233-123
10-1860
Issue 4 May 2002
pattern consistency test for all ports. If the transmitted and received bit patterns on
a trunk or port are different, the test fails.
When the test completes, the maintenance software sends a stop loop around
message to the UDS1 Interface circuit pack to put the circuit pack back into the
normal operation mode. All trunks or ports of the UDS1 Interface circuit pack are
restored to the in-service state after the release board command is entered.
Table 10-672.
TEST #135 Internal Looparound Test
Error
Code
Test
Result
Description/Recommendation
1002
ABORT
The system could not allocate time slots for the test. The system
may be under heavy traffic conditions or it may have time slots
out-of-service due to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy
traffic, repeat test at 1-minute intervals a maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the reset board command at
1-minute intervals a maximum of 5 times.
1004
ABORT
Received an incoming call on a port of the UDS1 circuit pack
during the test.
1. Enter busyout board UUCSS to put all trunks or ports of the
UDS1 Interface circuit pack to out-of-service state.
2. Retry reset board at 1-minute intervals a maximum of 5
times.
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied out
to out-of-service.
1. Enter busyout board UUCSS to put all trunks or ports of the
UDS1 Interface circuit pack into the out-of-service state.
2. Retry the reset board command.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...