Maintenance Object Repair Procedures
555-233-123
10-1258
Issue 4 May 2002
SCI Start Test (#176)
This test is destructive.
This test restarts the System Communication Interface. This implies all BX.25
(DCS, AUDIX, mis, etc.) and ISDN links are restarted. The checksum of the
downloadable firmware is tested. If the checksum fails, the firmware is
redownloaded from tape. If it passes, SCI Start completes and the associated
BX.25 and ISDN Links are started up. If a circuit pack needs to be replaced, refer
to
Chapter 6, ‘‘Reliability Systems: A Maintenance Aid’’
for instructions on
replacing an SPE circuit pack.
The Processor Interface circuit pack firmware is downloaded from the flash ROM
memory of Processor circuit pack. If the checksum test fails, then the firmware is
re-downloaded again from Processor circuit pack. If it passes, SCI Start
completes and the associated BX.25 and ISDN links are started up. If the
checksum failure persists, refer the footnote (b) of Hardware Error Table for repair
procedure.
Table 10-470.
TEST #176 SCI Start Test
Error
Code
Test
Result
Description/Recommendation
9
10
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1
FAIL
Could not reset the Processor Interface circuit pack.
1. Wait one minute, and retry the command.
2. If test continues to fail, replace TN765 Processor Interface
circuit pack. Refer to
Chapter 6, ‘‘Reliability Systems: A
for instructions on how to replace an SPE
complex circuit pack.
16
80
94
102
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If problem still exists, redownload firmware using the reset
interface command.
3. See note (b) of Hardware Error Table for repair procedure.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...