DIOD-DS1 (DS1 DIOD Trunk)
Issue 4 May 2002
10-593
555-233-123
DS1 CO Dial Tone Seizure Test (#314)
DS1 CO Dial Tone Seizure Test checks the trunk’s signaling capability provided by
the DS1 Interface circuit pack. The maintenance software initiates the test by
sending a “seizure” message to the DS1 Interface circuit pack and expects an
“active” reply from the DS1 interface circuit pack. If the “active” message is
received, then the test passes. If no message is received and the timer expires,
the test is aborted. If the DS1 Interface circuit pack sends a “reorder” message
back to maintenance software, then the test fails.
This test cannot be run on a trunk in any of the following conditions:
■
The trunk direction is administered as an incoming only trunk.
■
The trunk has been seized by a normal trunk call.
■
The trunk is administered with maintenance test disabled.
Table 10-220.
TEST #36 Port Audit and Update Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5
times.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
FAIL
Test failed due to internal system error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
Trunk translation has been updated successfully. The current
trunk states kept in the DS1 Interface circuit pack and switch
software are consistent. If the trunk is busied out, the test will
not run but will return PASS. To verify that the trunk is
in-service:
1. Enter the status trunk command to verify that the trunk is
in-service. If the trunk is in-service, no further action is
necessary. If the trunk is out-of-service, continue to step 2.
2. Enter the release trunk command to put the trunk back
into in-service.
3. Retry the test command.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...