change system-parameters maintenance
Issue 4 May 2002
A-19
555-233-123
Second OSS
Telephone
Number
The switch reports alarms secondly to the second OSS telephone number.
For example, INADS or DEFINITY SNMP. The number must be obtained
from the National Customer Support Center (NCSC) or the TSC. (# and * are
not allowed in the telephone number.)
Abbrev Alarm
Report
Enables the Abbreviated Alarm Report feature for the second OSS. (no)
Alarm
Origination to
OSS Numbers
Indicates one of four options for alarm origination (neither):
both
= Major and Minor alarms result in an automatic call to both
administered OSS telephone numbers.
first-only
= Major and Minor alarms result in an automatic call to the
first administered OSS number.
neither
= alarm origination does not occur; reports are not sent to either
number.
second no-backup
= Major and Minor alarms result in an automatic call
to the first administered OSS telephone number. If calling the first OSS
telephone number fails four times, the switch calls the second administered
OSS telephone number until calling the first OSS telephone number is
successful.
If Alarm Origination is deactivated, Cleared Alarm Notification and Restart
Notification deactivate, even though they may still be activate in the
administration.
Cleared Alarm
Notification
The switch originates calls to the OSS and sends an alarm resolution
message once all previously-reported Major and Minor alarms are resolved.
Activate Alarm Origination to enable Cleared Alarm Notification. (no)
Restart
Notification
Enables the switch to originate calls to the OSS and report any system
restarts caused by switch problems. Activate Alarm Origination to enable
Restart Notification.
Suspension
Threshold
Some problems cause alarms to be generated and resolved repeatedly. To
detect these problems, the switch suspends Cleared Alarm Notification when
it has reported the specified number of Cleared Alarm notifications in a 24
hour period. A suspended Cleared Alarm Notification reactivates with a
successfully-completed “logoff” command, a system reset, or when the
threshold is changed. This field is irrelevant if
Cleared Alarm
Notification
or
Alarm Origination
are disabled. (1–15)
Test Remote
Access Port
Indicates if remote access testing on the SYSAM circuit pack is active. This
field should be set to yes when an INADS line is connected to the switch and
a maintenance contract is in effect to maintain alarm origination capability.
If no equipment is connected to the remote access port, or if a trunk
for remote access and alarm origination is not provided, running tests
on the remote access port on the SYSAM results in test failures. This
causes unnecessary maintenance alarms and allows potentially
destructive tests to be run. To prevent this, set this field to no.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...