Maintenance Object Repair Procedures
555-233-123
10-1342
Issue 4 May 2002
2000
ABORT
Response to the test request was not received within the allowable
time period.
1. Retry the command at one-minute intervals a maximum of 5
times.
2. If the test continues to ABORT with Error Code 2000, check
for system powering problems with the A carrier (PPN or
EPN). Look for and resolve all AC-POWER and CARR-POW
alarms in a multicarrier cabinet system or DC-POWER alarms
in a single-carrier cabinet system. Repeat the test.
3. If the test continues to ABORT with a 2000 error code, check
for and resolve all DUPINT (Duplication Interface) errors in a
Duplicated Option PPN, PR-MAINT (Maintenance/Tape
Processor) errors in a standard PPN, or MAINT (EPN
Maintenance circuit pack) errors in an EPN. Repeat the test.
4. If the test continues to ABORT with a 2000 error code,
escalate the problem.
2028
ABORT
Internal System Error prevented the extinguishing of the Battery
Charger status LED.
1. Retry the command at one-minute intervals a maximum of 5
times.
2029
ABORT
Internal System Error.
1. Retry the command at one-minute intervals a maximum of 5
times.
Table 10-495.
TEST #5 Battery & Battery Charger Query Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...