Maintenance Object Repair Procedures
555-233-123
10-38
Issue 4 May 2002
1004
ABORT
The port was seized by a valid call during the test. The test
has been aborted.
1. Use the display port PCSSpp command to determine the
station extension.
2. Use the status station command to determine the
service state of the port. If the port is in use, it is
unavailable for certain tests. Wait until the port is idle
before testing.
3. When the port it idle, retry the command at 1-minute
intervals a maximum of 5 times.
1005
ABORT
This condition indicates that the test is not applicable when the
analog port is used in a combined modem pool. This error can
be ignored.
1018
ABORT
Test disabled via administration.
1. To enable the test for the particular analog station being
tested, enter the change station <extension> command
and change the “Test?” field on the Station Form from “n”
to “y.”
2000
ABORT
Response to the test request was not received within the
allowable time period.
2012
ABORT
System could not respond to this request.
2100
ABORT
Could not allocate the necessary system resources for this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Any
FAIL
The NPE of the tested port was found to be transmitting in
error. This causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots.
User-reported troubles on this port should be investigated by
using other port tests, by examining station wiring, or by
examining the station.
Table 10-14.
TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...