Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-302
Issue 4 May 2002
status attendant
This command diagnoses internal software. This command help to locate facilities
to which the attendant console communicates.
Output
The following output example is a display of status attendant 1.
Field descriptions
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
status
attendant
console
number
number assigned to an attendant (1 –16).
Report sent to printer.
Examples:
status attendant 1
status attendant 2
status attendant 2 print
init
inads
craft
cust
rcust
bcms
browse
none
none
Console Number
Number assigned to the attendant (1-16).
Port
Port location of the attendant
(cabinet-carrier-slot-circuit).
Service State
In-service/idle, in-service/active, out of service, or
disconnected.
Usage State
Idle or active.
Maintenance Busy State
Is maintenance testing the object? (y/n)
Connected Ports
Port locations to which the attendant is communicating
(cabinet-carrier-slot-circuit).
status attendant 1
ATTENDANT STATUS
Console Number: 1 Service State: in-service/night service
Port: 01C1106 Maintenance Busy? no
Connected Ports:
Command successfully completed
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...