STRAT-3 (Stratum 3 Clock)
Issue 4 May 2002
10-1561
555-233-123
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. In the context of the Stratum 3 clock, an OFF-BOARD alarm occurs when
there is a DS1 facility problem; otherwise, the alarm is ON-BOARD
indicating that there is a fault in the Stratum 3 clock or in the connection
between the Stratum 3 clock and the PBX (Private Branch Exchange)
switch. If the Stratum 3 clock cannot be referenced, and therefore the local
oscillator on the TN780 Tone-Clock circuit pack must serve as the
reference instead, a Major alarm is raised. Otherwise, a Minor alarm is
raised.
b. This error can be caused by one of the following conditions:
1. One or both TOCs (Timing Output Cards) may have failed,
2. the connection between the Stratum 3 clock and the TN780
Tone-Clock circuit pack may be faulty, or
3. the TN780 Tone-Clock circuit pack may be defective.
Stratum 3 Clock Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence. Refer to the appropriate test description and follow the recommended
procedures.
0
Any
Any
Any
test synchronization r 4
1 (d)
Any
Stratum 3 Clock
Alarm Query (#649)
MINOR
OFF
test synchronization r 4
257 (e)
Any
Stratum 3 Clock
Alarm Query (#649)
MINOR
OFF
test synchronization r 4
257 (c)
None
WARNING
ON
513 (f)
Any
Stratum 3 Clock
Alarm Query (#649)
MINOR
ON
test synchronization r 4
769 (g)
Any
Stratum 3 Clock
Alarm Query (#649)
MINOR
ON
test synchronization r 4
1025 (h)
Any
Stratum 3 Clock
Alarm Query (#649)
MINOR/MAJOR(a)
ON
test synchronization r 4
1281 (i)
Any
Stratum 3 Clock
Alarm Query (#649)
MINOR/MAJOR(a)
ON
test synchronization r 4
1537 (b)
none
MINOR/MAJOR(a)
ON
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...