Maintenance Object Repair Procedures
555-233-123
10-1282
Issue 4 May 2002
1
FAIL
The Packet Control parity circuitry is malfunctioning.
1. Issue test packet-control C long command to retry the
test.
2. This could be caused by a Packet Bus fault. Refer to
Chapter 9 for the procedures to be followed.
3. The Packet Control circuit pack needs to be replaced.
However, it is likely that the Packet Control is providing
service, and only its ability to maintain the Packet Bus is
affected by the fault. If the Packet Control appears to be
providing service (packet endpoints are functioning and/or
the status packet-control C command indicates that
links are established), it is not critical to replace the circuit
pack immediately, and a time may be chosen to minimize
customer down-time.
PASS
The Packet Control parity circuitry is functioning properly.
Table 10-480.
TEST #584 Packet Control Parity Circuitry Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page