Maintenance Object Repair Procedures
555-233-123
10-80
Issue 4 May 2002
FAIL
The terminal equipment is not connected to the circuit pack.
Some terminal equipment such as modems may fail even
when connected properly.
1. Remotely test the equipment.
2. If the test fails again, look for RING-GEN errors in the
error log. If present, refer to the RING-GEN (analog ring
generator) Maintenance documentation.
3. Check all of the wiring between the station equipment
and the switch. Then, run the test again.
4. If the test still fails, the set may be defective. Check the
set, and replace it, if necessary.
5. Some terminal equipment could fail even when it is
connected properly. If this is the case, disable the test
using the change station extension command (enter ’n’
into the Test field). Note that this action also disables
tests 6, 7, 161, and 35 on this port.
PASS
The station is connected properly to the switch. This test may
also pass if no terminal equipment is connected and the
terminal is located very far from the switch. User-reported
troubles on this port should be investigated by using other
port tests, by examining station wiring, or by examining the
station.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use the list config command, and resolve any problems
that are found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the
port. If this is not the case, dispatch to check to ensure
that there is a valid board inserted.
Table 10-29.
TEST #48 Station Present Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...