TONE-PT (Tone Generator)
Issue 4 May 2002
10-1811
555-233-123
Use display errors to look for errors on other circuit packs in the carriers of
the same Port Network as the indicated Tone-Clock. If any are found, they
should be resolved if possible, and the Tone-Clock circuit pack retested. If
this does not clear the problem, the Tone-Clock circuit pack should be
replaced and the new one tested. If the problem persists, follow
instructions for TDM Bus maintenance in this manual.
Tone Generator Update/Audit Test (#41)
The active tone generation facility is refreshed with all the time slot tone
information. This test also triggers in-line error messages the Tone-Clock circuit
pack generates when it detects problems by itself.
A check is also made between the type of tone-clock being tested and the type of
tone-clock needed based on system administration. The administration on the
system-parameters country-options form may imply that a TN780 or TN2182 is
required.
Table 10-658.
TEST #41 Tone Generator Update/Audit Test
Error
Code
Test
Result
Description/Recommendation
none
ABORT
The system was not able to allocate all the resources needed
for this test.
2100
ABORT
System resources required for this test are not available.
1
FAIL
The system requires a TN780 TN2182 tone-clocks to support
the currently administered country-options tone generation
parameters.
1. Check the administration on the system-parameters
country-option form. Specifically, the Base Tone
Generation Set on page 1 and any custom tone
administration beginning on page 2.
2. Replace existing tone-clock circuit packs with a TN780 or
TN2182.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...