ASAI-EPT
Issue 4 May 2002
10-173
555-233-123
ASAI-EPT
The maintenance strategy for this endpoint MO is built on maintenance facilities
offered in the Avaya ISDN-BRI protocol and in the ASAI adjuncts. Currently there
are no facilities in the protocol that provide for maintenance of set data features.
The TN800 is a PC-based platform that allows interaction of multiple applications
with DEFINITY at any time. DEFINITY Release 5 software (Native mode)
supports emulation of three types of port MOs on this board. The type of ports to
be emulated is defined by the applications running on the TN800.
NOTE:
If the TN800 is emulating BRI, the software/firmware supports a maximum
of 12 ports, but only 8 of the 12 ports can be administered at any one time.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
Full Name of MO
ASAI-EPT
MAJOR
1
1
The alarm level for ASAI adjuncts is administered using the set options command. The
alarm level can be set independently for off-board and on-board alarms to WARNING,
MINOR, or MAJOR for all ASAI adjuncts in the system.
test station extension
ASAI-Adjunct
Table 10-56. ASAI-EPT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
ASAI-EPT
On/
Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test ASAI-ADJ
2 (a)
2-102
None
257 (b)
Any
BRI Layer 3 Query
MAJ/WNG
2
OFF
test station ext r 2
test data-module ext r 2
351 (c)
0
none
WARNING
OFF
busyout and release
station
513 (d)
0
None
769 (e)
0
None
MAJOR
OFF
2561 (f)
0
None
2562-
2566 (g)
0
None
2567 (h)
0
None
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...