PPP-PT (Control LAN Packet/Port)
Issue 4 May 2002
10-1355
555-233-123
h. Error Type 2305-2816: System software detected a session is down. Aux
Data indicates the session number. These are log only errors. Error types
2305-2560 are for session numbers 1-256. Error types 2561-2816 are for
session numbers 257-512.
i. Error Type 3329: TCP/IP Ping Test failed.
1. Test the port (test port UUCSSpp short).
2. Refer to TCP/IP Ping Test (#1281) repair procedures.
j. Error Type 3585: TDM Port Looparound Test (#1285) failed.
1. Test the port (test port UUCsspp long).
2. Refer to TDM Looparound Test (#1285) repair procedure.
System Technician-Demanded Tests: Descriptions
and Error Codes
Investigate errors in the order they appear in the table below.
TDM Looparound Test (#1285)
NOTE:
This test is destructive.
This test verifies whether the CLAN PPP port can send and receive data on the
TDM bus. This test has a tone generator send tones on a timeslot, and it has a
tone receiver receive tones on another timeslot. The tones are looped through the
ppp port.
Table 10-499.
System Technician-Demanded Tests: PPP-PT
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive, ND = Non-destructive
TDM Looparound Test (#1285)
X
D
SCOTCH Synchronous Looparound Test (#1275)
X
D
TCP/IP Ping Test (#1281)
X
X
ND
Session Status Test (#1286)
X
X
ND
PPP Link Status Test (#1279)
X
X
ND
If the received tones:
Then:
Match the tones sent
The test passes
Do not match the tones sent
The test fails
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...