Table 10-11. TEST #9 NPE Crosstalk Test
Error
Code
Test
Result
Description/Recommendation
1
ABORT
During testing of the primary information channel, system
resources may not have been available. Also, the port may
have been busy during the test.
1. Check the port status (display port PCSSpp) to
determine the voice port extension of the port.
2. Use the status station command to determine the
service state of the port. If the port is in use, it is
unavailable for this test. Wait until the port is idle.
3. When the port it idle, retry the command at 1-minute
intervals a maximum of 5 times.
2
ABORT
System resources may not have been available, or the port
may have been busy during the test.
1. Check if port is being used (status station).
2. When the port it idle, retry the command at 1-minute
intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available.
The port may be in use.
1. Use the display port PCSSpp command to determine
the voice port extension of the port.
2. Use the status station command to determine the
service state of the port. If the port is in use, it is
unavailable for certain tests. Wait until the port is idle
before testing.
3. When the port it idle, retry the command at 1-minute
intervals a maximum of 5 times.
1001
ABORT
System resources required to run this test are not available.
Try (a)
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions, or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
“TDM-BUS” to diagnose TDM-BUS errors.
1. If system has no TDM-BUS errors, and if it is not handling
heavy traffic, retry the command at 1-minute intervals a
maximum of 5 times.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...