DIOD-TRK (DIOD Trunk) [G1.2SE]
Issue 4 May 2002
10-601
555-233-123
Dial Tone Test (#0)
This test attempts to seize a port and checks for the return of a dial tone.
Table 10-224.
TEST #0 Dial Tone Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate system resources to run this test.
1. Retry the command at one-minute intervals a maximum of
5 times.
1000
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call. Use the command
display port PCSSpp to determine the trunk group/member
number of the port. Use the status trunk command to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, then retry the command at
one-minute intervals a maximum of 5 times.
1001
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals a maximum of
5 times.
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS (TDM Bus) Maintenance documentation to diagnose
any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at one-minute intervals a
maximum of 5 times.
1004
ABORT
The port has been seized by a user for a valid call. Use the
status trunk command to determine when the port is available
for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...