DETR-BD
Issue 4 May 2002
10-519
555-233-123
DETR-BD
G1, G3iV1.1-286, and those G3iV2-386 systems that use the Mu-law companding
mode use TN748 Tone Detector circuit packs or TN756 combination Tone
Detector-Tone-Clock circuit packs. G3iV2-386 systems that use the A-Law
companding mode use TN420B (and higher suffixes) Tone Detector circuit packs.
The companding mode of the DETR-BD circuit pack must match that
administered for the system for proper tone detection. The companding mode is
administered on the System-Parameters Country-Options form. Refer to the
Administrator’s Guide for Avaya MultiVantage Software.
For all DETR-BD circuit pack level errors, refer to XXX-BD (Common Port Board)
Maintenance documentation.
DID-BD (Direct Inward Dial Trunk
Circuit Pack)
Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation for
circuit pack level errors. See also DID-TRK (DID Trunk) Maintenance
documentation for related trunk information.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1
Where P is the port network number (1 for PPN, 2 for EPN, and 3 for EPN2); C is the carrier number
(for example, A, B, C, D, or E); SS is the address of the slot in the carrier where the circuit pack is
located (for example, 01, 02, etc.).
Full Name of MO
DETR-BD
MINOR
test board PCSS
Tone Detector Circuit Pack
DETR-BD
WARNING
test board PCSS
Tone Detector Circuit Pack
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1
Where P is the port network number (1 for PPN and 2 or; C is the carrier designation (for example,
A, B, C, D, or E); and SS is the address of the slot in the carrier where the circuit pack is located (for
example, 01, 02, etc.).
Full Name of MO
DID-BD
MIN
test board PCSS sh
Direct Inward Dial Trunk Circuit Pack
DID-BD
WRN
test board PCSS sh
Direct Inward Dial Trunk Circuit Pack
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...