Maintenance Object Repair Procedures
555-233-123
10-552
Issue 4 May 2002
Notes:
a. Error Type 1: this error reports the registration status of the endpoint. If call
processing SW claims the endpoint is registered and receives keep-alive
handshakes from the endpoint, the test passes. If keep-alive handshaking
has failed, the test fails. If the user has intentionally un-registered from
Avaya DEFINITY Server, the station is now basically an AWOH station and
is no longer being maintained; no tests run for this station.
b. Error Type 18: this error type is logged when the port/station is busied out
by maintenance personal. Make sure the port/station is released from busy
via the release port/station command (IP terminal only).
c. Error Type 257: this error tracks failures of the signaling path PING test.
The test attempts to send a PING packet to the endpoint IP address, as
reported during registration. The PING packet originates with the C-LAN
board through which the endpoint is registered. If the PING response
packet is received, the test passes. If the PING response packet times out,
the test fails.
Table 10-201.
DIG-IP-STN Digital IP Station Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
0
Any
Any
test station extension
1 (a)
Registration Status Inquiry
(#1372)
WARNING
OFF
18 (b)
0
Busyout port or station
WARNING
OFF
release port (or)
station
257 (c)
Signaling Path PING Test
(#1373)
WARNING
OFF
(d)
Digital Terminal Lamp
Update (#16)
WARNING
OFF
(e)
Digital Terminal Audit
Update (#17)
WARNING
OFF
513 (f)
Any
Station Digital AUDIT Test
(#17)
WARNING
OFF
test port or station
1281
(g)
Any
Station Digital AUDIT Test
(#17)
WARNING
OFF
test port or station
1537
(h)
40968
WARNING
OFF
test port or station
2305 (i)
Any
None
2817 (j)
Station Hyperactivity
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...