Maintenance Object Repair Procedures
555-233-123
10-1856
Issue 4 May 2002
NPE Connection Audit Test (#50)
The system sends a message to the on-board microprocessor to update the
network connectivity translation for the SCOTCH-NPE chip on the circuit pack.
Table 10-669.
TEST #50 NPE Connection Audit Test
Error
Code
Test
Result
Description/Recommendation
None
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1019
ABORT
The test aborted because a test was already running on the port.
1. Retry the command at 1-minute intervals for a maximum of
5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS
The circuit pack’s SCOTCH-NPE chip has been updated with its
translation.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted,
an incorrect board is inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Execute the
add ds1 UUCSS command to administer the UDS1
interface if it is not already administered.
2. If the board was already administered correctly, check the
error log to determine whether the board is hyperactive. If
this is the case, the board is shut down. Reseating the
board will re-initialize the board.
3. If the board was found to be correctly inserted in step 1,
then issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal ID and
the port.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...