Maintenance Object Repair Procedures
555-233-123
10-34
Issue 4 May 2002
ADX16A-PT (AUDIX Analog
Line/Control Link)
!
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow the
instructions on the TN566/TN2169 faceplate:
■
Remove EMBEDDED AUDIX circuit packs
■
Cycle power to a carrier containing EMBEDDED AUDIX circuit packs
■
Remove power to a carrier containing EMBEDDED AUDIX circuit packs
The ADX16A-PT maintenance object represents a port on a TN566/TN2169
EMBEDDED AUDIX circuit pack that is operating in control-link (CL) mode. For
circuit-pack-level problems (ADX16A-BD or ANL-16-BD), see “XXX-BD (Common
Port Circuit Pack)”. For port-level problems with AUDIX operating in digital-port
mode, see ADXDP-PT/ADX8D-PT.
The tests described in this section apply only to switch-side maintenance which
tests circuit pack components related to the TDM bus interface. The AUDIX
system has an extensive maintenance strategy that is described in EMBEDDED
AUDIX System Maintenance, 585-300-110.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction Board
(MFB) and the TN2169 Alarm Board (ALB). Because of its size this combination
occupies 5 slots, but only 1 slot is functional as far as the switch is concerned. The
other 4 slots are seen by the switch as “AUDIX-reserved” slots.
In CL mode the TN566 pack supports up to 16 voice ports. When a call to a
station with an AUDIX login is not answered, AUDIX answers the call using one of
the available voice ports.
Unlike other AUDIX systems, EMBEDDED AUDIX is not an adjunct.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command To
Run
1
1
UU is the universal cabinet number (1 for PPN, 2 - 3 for EPNs). C is the carrier designation (A, B,
C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21). pp is the two
digit port number (01, 02,...).
Full Name of MO
ADXCL-PT or
ADX16A-PT
MINOR
test port PCSSpp l
AUDIX Analog Line/ Control Link
ADXCL-PT or
ADX16A-PT
WARNING
test port PCSSpp sh
AUDIX Analog Line/ Control Link
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...