VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 4 May 2002
10-1945
555-233-123
1. Refer to Congestion Query Test (# 600) for Abort and Fail 3601s.
o. Error Type 3073: Remote Socket Control Link (RSCL) or Link Status Test
(#601) failed. This failure can be due to:
■
This circuit pack
■
The packet bus
■
The packet interface circuit pack.
p. Error Type 3330: Critical failure in Packet Bus interface.
Below, Error Types correspond to descriptions.
1. Attempt to clear the alarm (reset board UUCSS).
2. If alarm persists, replace circuit pack.
q. Error Type 3586 and 3999: Switch removed hyperactive circuit pack that
reported threshold number of errors. One or more of the following
symptoms can be present:
■
Circuit pack port tests return NO BOARD.
■
List configuration command shows circuit pack and ports are
installed properly
If:
Then:
Active buffers exceed threshold,
VAL enters congested state.
If:
Then:
RSCL disconnects at link level
Link fails
Link cannot be reconnected quickly
Switch raises MINOR alarm
If the switch detects:
Then it:
1 error,
Resets circuit pack.
2 errors in 15 minutes,
Raises MINOR alarm.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...