PR-MAINT (Maintenance Processor [TN2404/TN790
RISC Systems])
Issue 4 May 2002
10-1369
555-233-123
MTP Reset Test (#101)
This test is destructive.
The test resets the Maintenance Processor. The destructive nature of this test
causes the following:
■
System Access Terminal to log off
■
DCE port to terminate data transmission
■
Any current memory card access to terminate and also to tear down any
remote access INADS connection
Table 10-506.
TEST #101 MTP Reset Test
Error
Code
Test
Result
Description/Recommendation
100
ABORT
The requested test did not complete within the allowable time
period.
1. Retry the command.
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to “STBY-SPE” for a description of these error codes.
2500
ABORT
Internal system error
1. Retry at 1-minute intervals a maximum of 5 times.
Continued on next page