TDM-CLK (TDM Bus Clock)
Issue 4 May 2002
10-1735
555-233-123
Standby Reference Health Check Test (#651)
This test evaluates the quality of the external synchronization timing source for a
standby Tone-Clock circuit pack. All administered synchronization timing sources
must be valid for this test to pass. If the tone-clock circuit pack and the
synchronization timing sources are in different port networks, the EI circuit packs
transport the timing sources to the tone-clock.
Table 10-641.
TEST #651 Standby Reference Health Check Test
Error
Code
Test
Result
Description/Recommendation
ABORT
This test may already be running due to a tone-clock
installation, scheduled maintenance, alarm activity, or a
technician-demand test from another terminal. This abort can
also occur due to an internal system error.
1. Try the command again at 1-minute intervals up to 5
times.
1184
ABORT
This test requires an external synchronization source to be
administered (DS1 primary, DS1 primary and secondary, or
Stratum 3 Clock).
1. Administer the external synchronization source and retry
the test.
2500
ABORT
Internal System Error
1. Try the command again at 1-minute intervals up to 5
times.
0
FAIL
The external synchronization timing source for side A of the
Stratum 3 clock, or for the primary DS1 reference is either
absent or invalid. The external synchronization timing source
for side B of the Stratum 3 clock, or for the secondary DS1
reference is not yet tested.
1
FAIL
The external synchronization timing source for side B of the
Stratum 3 clock, or for the secondary DS1 reference is either
absent or invalid.
1. Correct the synchronization source problem. Refer to the
Synchronization (SYNC) maintenance section of this
manual.
2. If the error still exists, replace the Tone-Clock circuit pack
reported in the error log. See How to Replace the
Tone-Clock Circuit Pack in the TONE-BD section.
PASS
The external synchronization timing source is valid.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...