Maintenance Object Repair Procedures
555-233-123
10-946
Issue 4 May 2002
Signaling Link Board Check (#643)
This test checks the state of the UDS1 Interface circuit pack (TN464C or later)
transporting the ISDN-PRI Signaling Link.
Table 10-346.
TEST #643 Signaling Link Board Check
Error
Code
Test
Result
Description/Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1700
ABORT
Rollabout video abort. The PRI terminal adapter associated
with this D-channel port is detached from the circuit pack. This
is a normal abort when the rollabout video feature is enabled.
To complete test on this port, either:
1. Re-attach the disconnected PRI terminal adapter and
retry test command, or
2. Disable the rollabout video feature on this circuit pack by
entering change ds1 PCCSS and set the field “Alarm
when PRI Endpoint Detached?” to “y.”
8
FAIL
The UDS1 circuit pack (TN464C or later) is not in-service.
1. Check the Hardware Error Log for entries logged against
UDS1-BD and consult the UDS1-BD (UDS1 Interface
Circuit Pack) Maintenance documentation for repair
procedures.
PASS
The UDS1 Interface circuit pack transporting the ISDN-PRI
Signaling Link Port is in-service.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...