Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-30
Issue 4 May 2002
If, during the execution of a command, a resource problem occurs that requires
the user to restart the command, then the following message appears:
Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the
following message appears:
All maintenance resources busy; try again later
clear isdn-testcall
Help Messages
If the system technician presses
HELP
after entering “clear isdn-testcall,” the
following appears:
Enter group #/member #
Error Messages
If the specified format of the trunk location is incorrect, this message displays:
Format invalid
If the specified trunk group or member range is invalid, this message displays:
Trunk or trunk group invalid
If a trunk group and member is not specified, this message displays:
Must specify group/member pair
If the specified trunk group is not administered or has no members administered,
this message displays:
Group not assigned, or group assigned but with no member
If the specified trunk group member is not administered, this message displays:
Group member not assigned
If the board on which the port resides is not administered, this message displays:
Port not assigned
If a test call is currently not in progress when the command is entered, this
message displays:
Test Call not in progress
If the specified trunk is not an ISDN-PRI trunk, this message displays:
Invalid non ISDN-PRI trunk specified
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...