S-SYN-PT (Speech Synthesis Port)
Issue 4 May 2002
10-1475
555-233-123
Speech Synthesis DTMF Receiver Test (#163)
A series of DTMF tones are conferenced from the TDM Bus into the port’s DTMF
receiver and checked to see if the correct tones have been detected during the
correct intervals. If all the DTMF tones were detected correctly, the test passes. If
any of the tones were not detected correctly, the test fails.
Table 10-558.
TEST #163 Speech Synthesis DTMF Receiver
Error
Code
Test
Result
Description/Recommendation
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals a maximum of
5 times.
1000
ABORT
System resources required to run this test are not available.
The port may be busy with a valid call and therefore
unavailable for certain tests. You must wait until the port is idle
(yellow LED if off) before retesting.
1. If the port is idle, retry the command at one-minute
intervals a maximum of 5 times.
2000
ABORT
Response to the test request was not received within the
allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals a maximum of
5 times.
Any
FAIL
DTMF tones were not detected. This type of failure may cause
features using touch-tone input to the Speech Synthesis Port
to malfunction.
1. Verify that the Tone-Clock circuit pack is functioning
correctly by checking the Error Log and using the test
tone-clock long command.
2. If the test fails again, replace the Speech Synthesis circuit
pack.
PASS
The port has detected all DTMF tones correctly. User-reported
troubles should be investigated using other tests and verifying
other ports on this circuit pack are working correctly.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...