Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-10
Issue 4 May 2002
busyout mis
This command places the management information system in the maintenance
busy state. No periodic or scheduled maintenance is performed until it is released.
When the object is busied out no call processing activity may be performed over
the link. A warning alarm (error type 18) is generated on the busied out mis, so
that INADS can determine its state. The command, release mis, reactivates the
busied out mis.
Output
The following example shows the output from the busyout mis command. The
responses display on a test-by-test basis with one line of data for each test result.
Field descriptions
Action/Object
Qualifier
Qualifier
Description
Logins
Defaults
Feature
Interactions
busyout mis
Example:
busyout mis
init
inads
craft
cust
rcust
None
None
Port
Not applicable
Maintenance Name
Name of busied out maintenance object:
MIS
Alt. Name
Not applicable
Result
Test result: Pass, Abort, Fail
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of codes by test number for each MO.
busyout mis SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
MIS PASS
Command Successfully Completed
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...