Maintenance Object Repair Procedures
555-233-123
10-158
Issue 4 May 2002
b. This error is logged and the port is alarmed when an alarm is raised on the
Announcement circuit pack because of a faulty condition with a common
circuit pack resource. Any one of the following alarmed errors on the
Announcement circuit pack causes this error to be logged against the
Announcement Port: 1793, 2049, 2305, 2561. Follow the ANN-BD
(Announcement Circuit Pack) Maintenance documentation to resolve these
alarms. When the corresponding circuit pack alarm is cleared, this alarm
clears.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Channel
Administration Memory Array (CAMA) Test, for example, you may also clear
errors generated from other tests in the testing sequence.
Channel Administration Memory Array (CAMA)
Test (#205)
This test is a memory device that stores information used to control the 140AY
device. The Angel asynchronously feeds the CAMA with the control information.
During the CAMA test, the Angel writes patterns into the CAMA, reads them back,
and verifies that they match. If the patterns do not match, the test fails. This test is
run periodically by the switch maintenance and by the Announcement circuit pack
in the background.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1
D = Destructive; ND = Nondestructive
Channel Administration Memory Array (CAMA) Test (#205)
X
ND
Playback Speech Memory Array (PSMA) Test (#206)
X
X
ND
140AY Channel Sanity Inquiry Test (#222)
X
X
ND
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...