MODEM-PT (Modem Pool Port)
Issue 4 May 2002
10-1101
555-233-123
Hardware Error Log Entries and Test to Clear
Values
Note:
a. This error type indicates that the circuit pack has been removed or has
been insane for more than 21 minutes. To clear the error, reinsert or
replace the circuit pack.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Modem Pool
Conference Test, for example, you may also clear errors generated from other
tests in the testing sequence. The tests in this section do not apply to Combined
Modem Pool conversion resources. The standard Digital Line and/or Analog Line
port tests are run on the ports associated with the Combined Modem Pool. The
test descriptions for those maintenance objects (MOs) should be consulted when
repairing Combined Modem Pool arrangements.
Modem Pool Port Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
18
0
busyout PCSS
WARNING
OFF
release port PCSSpp
130 (a)
None
WARNING
ON
test port PCSSpp sh
257
Conversion Resource
Loop Test (#98)
MINOR
ON
test port PCSSpp sh r 3
513
Modem Conference
Test(#97)
MINOR
ON
test port PCSSpp l r 3
769
Modem NPE
Crosstalk Test (#96)
MINOR
ON
test port PCSSpp l r 3
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...