AN-LN-PT (Analog Line Port)
Issue 4 May 2002
10-129
555-233-123
Looparound Test (#161)
This test checks the on-board transmission capabilities of the NPE, the codec,
and the battery feed chip of the analog port. The test passes if the signal
measured by the tone detector is within acceptable limits.
Table 10-43. TEST #161 Looparound Test
Error
Code
Test
Result
Description/Recommendation
ABORT
Necessary system resources could not be allocated to run this
test.
1. Retry the command at 1-minute intervals no more than 5
times.
2. If the test continues to abort, escalate the problem.
1000
ABORT
System resources are unavailable. The port may be busy with
a valid call. This result is also reported for the system’s
Music-On-Hold port when it is off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the station’s
extension.
2. Enter status station extension to determine the service
state of the port.
3. If the port is in use, wait until the port is idle. Retry the
command at 1-minute intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
1002
ABORT
The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or have time
slots out-of-service due to TDM-BUS errors.
1. Refer to “TDM-BUS” to diagnose any active TDM-BUS
errors.
2. If the system has no TDM-BUS errors and is not handling
heavy traffic, retry the command at 1-minute intervals no
more than 5 times.
3. If the test continues to abort, escalate the problem.
1003
ABORT
The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Resolve any TTR-LEV errors in the Error Log.
2. Resolve any TONE-PT errors in the Error Log.
3. If neither condition exists, retry the command at 1-minute
intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...