Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-376
Issue 4 May 2002
Field descriptions, page 3
NOTE:
A dash (-) or a colon “1” between numbers indicates all numbers including
and between the indicated numbers.
TCP/IP Applications Currently Active (page 4)
The following is an example of the output of page 4 of status link n. The form
displays all the TCP/IP socket links that are currently up and active that are using
the ethernet link n via the CLAN board or the Processor Ethernet interface.
UP:
Channels are up.
DN:
Channels are down.
PND:
Channels are in a pending state from the down to the up
state (processor channels only)
status link 1 Page 3 of 3
PROCESSOR CHANNEL STATUS
UP: 001, 007, 010-115
199, 300:310
DN: 001-002
PND: 003, 216-220, 299
status link 1 Page 4 of 4
TCP/IP Applications Currently Active
Service Type Sessions
ALARM1 1
ALARM2 1
CDR1 1
CDR2 1
DOLAN 356
PMS 1
PMS_JRNL 1
PMS_LOG 1
SAT 4
SYS_PRNT 1