ASAI-RES/E-DIG-RES (TN800 reserve slot)
Issue 4 May 2002
10-193
555-233-123
ASAI-RES/E-DIG-RES (TN800 reserve
slot)
There are no tests associated with these MOs. Both the test board and busy out
board commands abort when either is attempted on a reserved slot. An error
message indicates the slot is associated with the circuit pack that the TN800 is
emulating, but the requested operation is not valid.
The TN800 MAPD (Multi-Application Platform for DEFINITY) circuit pack
connects to the switch through a single slot in the backplane. The number of slots
occupied by the MAPD pack is supplied by the board when inserted. The TN800
in R5EM is 3 slots wide. The TN800 requires 2 reserve slots to its left. The reserve
(blank) slots are to left of the functional slot and are place holders on the switch,
and do not have any interaction with the switch.
Each instance of these MOs represents a reserve slot associated with respective
circuit pack mode in which the MAPD is working.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
Full Name of MO
ASAI-RES
NONE
NONE
TN800 ASAI reserve slot
E-DIG-RES
NONE
NONE
TN800 DIG reserve slot
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...