Maintenance Object Repair Procedures
555-233-123
10-676
Issue 4 May 2002
1005
ABORT
CPE Loopback Jack Test cannot be executed in the current
configuration. To run this Test, the TN767E or later suffix DS1 must
be administered for 24-channel operation. The "Bit Rate" field on
the DS1 circuit pack administration form must be set to "1.544" for
24-channel operation.
1015
ABORT
Ports on the DS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put all trunks or
ports of the DS1 Interface circuit pack into the out-of-service
state.
2. Retry the command.
1039
ABORT
The DS1 Interface circuit pack is providing timing for the system.
Executing this test could cause major system disruption.
If the DS1 Interface circuit pack needs to be tested, set the
synchronization reference to another DS1 Interface circuit pack or
to the Tone-Clock circuit pack via the following command
sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch command.
1950
ABORT
Another loopback/span test is already executing on the DS1 board
or the board is in a network requested loopback mode (Line
loopback or Payload loopback). The hardware error log will indicate
whether a Customer Loopback Jack Test, Far CSU Loopback Test,
or the One-Way Span Test is executing or if the board is in line
loopback or payload loopback mode. Only one long-duration
loopback/span test can be active at a given time. Thus, if a
loopback/span test is already active, that test must be terminated
via the test ds1-loop UUCSS end-loopback/span-test command in
order to execute this test.
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals for a maximum of 5
times.
Table 10-247.
TEST #1212 CPE Loopback Jack Test — Continued
Error
Code
Test
Result
Description/Recommendation
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...