TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
Issue 4 May 2002
10-1677
555-233-123
CRC Error Counter Test (#623)
This test is non-destructive.
This test reads the BRI port’s CRC error counters that are maintained on the BRI
circuit pack. The Cyclic Redundancy Check (CRC) is a means of error detection
used to determine the integrity of data frame contents. The CRC error counter is
incremented by the circuit pack when it detects a CRC error. The test passes if the
value of the counter is 0 (that is, the error is cleared). If the counter is non-zero,
the test fails, and the value of the counter is displayed in the
Error Code
field.
Table 10-616.
TEST #623 CRC Error Counter Test
Error
Code
Test
Result
Description/Recommendation
ANY
FAIL
This error occurs when a frame with a bad CRC is received
over the D-Channel by the BRI board. This error is reported
on a per-port basis when the counter goes over the threshold.
This error is most likely due to a problem with the wiring or
interference on the wiring caused by a noise source or no
termination. It usually does not indicate a problem with the
circuit pack.
PASS
The CRC error counter was read correctly and has a value of
0.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...